Build Guide - Calibration

 

 

  1. Set [RESONANCE] and [FREQUENCY] to maximum
  2. Set P1 to its mid-position
  3. Monitor the wiper of P4 and adjust it for 0.0V
  4. Set P2 to its mid-position
  5. Monitor [OUT] which should be oscillating. If not, back off the [FREQUENCY] control slowly until it does
  6. Set [RESONANCE] to '8'
  7. Adjust P2 (normally this will be a clockwise rotation) until the oscillations stop
  8. Set [RESONANCE] to maximum, the oscillations should restart
  9. Repeat steps (6) to (8) if needed
  10. Set [FREQUENCY] to its mid-position
  11. Adjust P4 for a frequency of approximately 200Hz

 