Build Guide - Calibration

 

                  1. Set P3 fully clockwise
                  2. Set P4 to its mid-position
                  3. Apply 0V to [CV+]
                  4. Set [CV+] to maximum
                  5. Set [CV-] to minimum
                  6. Set [MIX] to ‘DRY’
                  7. Patch [OUT] to [IN]
                  8. Set [MODE] to [HP]
                  9. Monitor [OUT]
                  10. Set [FREQUENCY] to maximum
                  11. Set [RESONANCE] to maximum
                  12. Adjust P4 for a frequency of ~16kHz
                  13. Set [MODE] to [NOTCH]
                  14. Adjust [FREQUENCY] for an output frequency of 100Hz
                  15. Apply 3V to [CV+]
                  16. Adjust P3 for 800Hz
                  17. Repeat steps (13) to (16) until a repeatable result is obtained
                  18. Set [FREQUENCY] to maximum
                  19. Set [MODE] to [HP]
                  20. Adjust P4 for a frequency of ~16kHz

The 1V/Octave setting is an approximate one as the tracking will never be accurate