Build Guide - Calibration

 

If fitted, set [INITIAL GAIN] to 0V (fully CCW).
Set P2 and P3 to their mid-positions.
1. Connect a10Hz 5VDC triangle signal to [VC 1]
2. Set [GAIN] to maximum
3. Monitor [OUT] with a scope in the 100mV range(*)
4. Adjust P3 (OFFSET) to set any DC offset close to 0V
5. Adjust P2 (CV REJECT) to reduce any breakthrough to minim
6. Repeat steps (4) and (5) until an optimum result is achieved
7. Connect a 440Hz 5VAC triangle to [IN 1]
8. Connect a 5VDC signal to [VC 1]
9. Adjust P1 (CV INIT) until the output is 5VAC.