Build Guide - Calibration
  1. Switch both the [JOIN] switches to the OFF position
  2. Set all 3 level controls to maximum
  3. Monitor [AC OUT] on Column 1
  4. Patch a 100Hz 5VAC triangle wave in to [INPUT 1]
  5. Adjust P101 for 5Vp-p at the output
  6. Monitor [AC OUT] on Column 2
  7. Patch the triangle wave in to [INPUT 2]
  8. Adjust P201 for 5Vp-p at the output
  9. Monitor [AC OUT] on Column 3
  10. Patch the triangle wave in to [INPUT 3]
  11. Adjust P301 for 5Vp-p at the output
If you do not have access to an oscilloscope then a multimeter set to AC Volts can be used

 