The Synth-A-Scope Module offers the user the opportunity to build their own oscilloscope in to any package they desire.
This module is for the core oscilloscope which requires some additional circuitry in the form of an input buffer and range circuit. User control switches are simply wired direct to their relative points on the header. A suggested circuit for these is show here.
We currently use this module in our 3U ED702 Synth-A-Scope and 5U ED702D Synth-A-Scope but it can just as easily be built in to a 4U unit or a dedicated housing of your own choice.
Parameter |
Value |
Real-time sampling rate |
1MSPS (max) |
Sensitivity |
1V/div - 5V/div in "1-2-5" steps |
Timebase |
10uS/div - 500uS/div in "1-2-5" steps |
Capture buffer size |
1024 bytes |
Trigger modes |
Automatic/Normal/Single |
Display size |
2.4" (61mm) |
Display resolution |
320 pixels x 240 pixels |
Input impedance |
1M ohm/20pF |
ADC resolution |
12-bits |